Thulium Laser Settings Explained - Energy, Pulse Width, Spot Spacing & Overlap

Thulium Laser Settings Explained - Energy, Pulse Width, Spot Spacing & Overlap

Pure Tone Journal · Professional Laser Technology

Thulium Laser Settings Explained

Understanding energy, pulse width, spot spacing and overlap in professional fractional laser treatments.

For practitioners using or considering 1927nm Thulium and 1550nm Erbium Glass, understanding the treatment parameters is just as important as understanding the wavelengths.

Energy settings, pulse duration, spot spacing, treatment coverage and repeated scans all influence how laser energy is delivered to the skin.

In this guide, we explain the principal controls found on the Thulium Laser Pro Dual™ and why they matter when planning professional skin-rejuvenation treatments.

Aesthetic nurse Donna Cummings using the Pure Tone Thulium Laser Pro treatment interface during a professional demonstration
Donna Cummings, Aesthetic Nurse, demonstrating the Thulium Laser Pro™ during professional laser training.

The central principle

A Single Setting Doesn't Determine Treatment Intensity

It is tempting to judge a fractional laser treatment by one number, usually the energy setting.

In practice, the response of the skin depends on a combination of parameters.

Pulse energy and duration influence the energy delivered during a pulse.

Spot spacing affects how closely treatment points are positioned.

Repeated scans and treatment passes influence the amount of exposure received by an area.

The selected wavelength determines how that energy interacts with tissue.

These settings must therefore be considered together rather than independently.

Understanding laser controls

What Do the Main Settings Mean?

The Thulium Laser Pro Dual™ provides adjustable controls that influence the delivery and distribution of fractional laser energy.

Energy · mJ

Pulse Energy

The amount of energy delivered in an individual laser pulse or treatment point, as defined by the device.

Pulse Width · ms

Pulse Duration

The length of time over which laser energy is delivered during an individual pulse.

Power · W

Laser Power

The rate at which laser energy is delivered. Power, pulse duration and pulse energy are related, but are not interchangeable.

Space

Spot Spacing

Controls the spacing between individual fractional treatment points within the selected scan pattern.

Overlap

Repeated Scans

Controls the number of scan repetitions on the machine.

This should not be confused with a percentage-based overlap measurement.

Scan Area

Coverage

Determines the shape and dimensions of the selected area over which the laser is delivered.

Parameter one

Energy, Power and Pulse Width

Three related measurements that are often confused, but describe different aspects of laser delivery.

What Is Laser Energy?

Laser energy is measured in millijoules (mJ).

One millijoule is one-thousandth of a joule.

On the Thulium Laser Pro Dual™, the energy values in the treatment parameter tables are expressed in mJ for both the 1927nm and 1550nm wavelengths.

The energy setting contributes to the amount of thermal interaction created at each treatment point.

However, higher energy does not automatically mean a better result. The selected wavelength, pulse duration, spot distribution and overall treatment protocol all matter.

What Is Pulse Width?

Pulse width is measured in milliseconds (ms) and describes the duration of a laser pulse.

Delivering energy over a shorter or longer period can change the way heat is deposited and dissipated within tissue.

Pulse width should therefore be considered alongside pulse energy, not simply viewed as a separate comfort setting.

What Is Laser Power?

Power is measured in watts (W) and describes the rate of energy delivery.

The machine's operating manual states that the displayed energy is calculated from power and pulse width.

In basic physical terms, energy is the product of power and time.

A Useful Technical Distinction

Energy is not the same as power.

A watt describes energy delivered per second. A millijoule describes a quantity of energy. A millisecond describes duration.

Understanding the difference helps practitioners interpret the treatment interface and compare protocol information more accurately.

The exact relationship between displayed parameters and emitted laser pulses must always be understood in the context of the specific device.

Parameter two

Spot Spacing and Fractional Treatment Density

Fractional laser treatments deliver energy to multiple small treatment zones rather than uniformly treating the entire skin surface.

The spot spacing setting influences how far apart those treatment points are positioned.

When treatment points are closer together, more points may be placed within a given area.

When they are further apart, fewer points may be delivered to the same area.

This has implications for overall treatment coverage and the proportion of tissue exposed to laser energy.

It is important, however, not to assume that a particular spacing number has the same meaning on every laser system.

Manufacturers may use different units, scan geometries or density calculations.

For this reason, settings taken from another laser platform should not be directly transferred to Thulium Laser Pro Dual™.

Why Spacing Matters

Treatment intensity is affected not only by the energy delivered at an individual point, but also by how many points are delivered across the treated area.

Two treatments using the same pulse energy can produce different overall tissue responses if their fractional coverage differs.

Pulse energy and treatment density should always be considered together.

Parameter three

Overlap, Repeated Scans and Treatment Passes

The term overlap can mean different things in laser treatment literature.

On some systems, it refers to the degree to which adjacent laser spots physically overlap.

On the Thulium Laser Pro Dual™ interface described in the manual, the Overlap control refers to the number of scan repetitions.

That distinction is important. It should not be interpreted as a percentage of overlapping spot diameter.

Repeating a scan can increase the total energy exposure delivered to the selected area.

The effect depends on the number of repetitions, their spatial distribution, the interval between pulses and the selected energy settings.

Practitioners must also consider any additional manual passes over the same skin.

The Cumulative Effect

A treatment does not necessarily remain gentle simply because the individual pulse energy is relatively low.

Closely spaced treatment points, repeated scans and additional passes can increase the cumulative thermal effect.

This is why the overall protocol matters more than any single displayed setting.

Treatment area and distribution

Scan Patterns, Coverage and Delivery Sequence

Thulium Laser Pro Dual™ provides selectable scan shapes and treatment area dimensions.

These allow the practitioner to configure how fractional treatment points are distributed within a selected area.

The manual describes geometric patterns including rectangular, triangular, circular and hexagonal shapes.

It also describes different emission sequences, including sequential, centre-outward and random delivery.

These controls are relevant to treatment coverage and the spatial and temporal distribution of energy.

They do not replace the need for correct handpiece positioning, appropriate eye protection or careful selection of the treatment area.

Treatment Shape

Allows the scan footprint to be matched to the selected area, within the machine's available configurations.

Area Dimensions

Allow the width and length of the scan footprint to be adjusted for the treatment area.

Emission Order

Determines the sequence in which individual treatment points are delivered across the selected pattern.

Close-up of a professional Thulium Laser Pro facial skin rejuvenation treatment showing the handpiece and patient eye protection
A professional 1927nm Thulium treatment in progress. Handpiece positioning, patient protection and consistent coverage remain important alongside the selected settings.

Two wavelengths, different tissue interactions

Why 1927nm and 1550nm Need Different Treatment Parameters

Thulium Laser Pro Dual™ combines two established fractional laser wavelengths:

  • 1927nm Thulium
  • 1550nm Erbium Glass

Both wavelengths interact with water in the skin, but they have different absorption characteristics and typical treatment depths.

As a result, their settings cannot simply be treated as equivalent.

1927nm Thulium

1927nm has relatively strong water absorption and is commonly used for superficial fractional skin renewal.

Its treatment applications include selected pigmentation, uneven tone, photoageing and superficial texture concerns.

Treatment intensity can vary considerably, and higher settings on the Pure Tone system can produce visible surface ablation.

1550nm Erbium Glass

1550nm Erbium Glass is a non-ablative fractional wavelength commonly used for deeper dermal remodelling.

It may be selected for textural concerns, acne scarring, fine lines and collagen remodelling.

Its treatment response depends on energy, density, pulse characteristics and patient selection.

Why They Differ

The wavelengths create different patterns of tissue interaction.

The same number of millijoules does not necessarily produce the same biological effect when delivered at different wavelengths.

Each wavelength requires its own appropriate clinical treatment plan.

For a more detailed explanation of the technology, read our guide to 1927nm Thulium and 1550nm Erbium Glass .

The clinical principle

Treatment Intensity Is Cumulative

A practitioner needs to understand the combined effect of the selected parameters, not just the energy figure on the screen.

Energy per Point

Contributes to the thermal interaction created at each fractional treatment location.

Fractional Coverage

Influences how much tissue is exposed within the selected treatment area.

Repeated Exposure

Additional scans and passes may increase the total energy delivered to an area.

The Importance of Visible Skin Response

1927nm Thulium is usually described as a non-ablative fractional technology.

However, on Thulium Laser Pro Dual™, very high settings can produce visible surface ablation.

That means there is a meaningful difference between a gentle treatment intended to produce limited surface disruption and a more intensive protocol associated with a stronger epidermal response.

The observed tissue response must therefore form part of treatment assessment.

A practitioner should not assume that all 1927nm treatments have the same recovery profile merely because they use the same wavelength.

The possibility of visible ablation is also relevant when considering whether additional 1550nm treatment during the same appointment would be appropriate.

Applying the technical knowledge

How Practitioners Should Approach Treatment Planning

The machine's reference parameters provide a starting framework, but the patient determines the clinical plan.

Before selecting energy, pulse width, spacing or scan repetitions, the practitioner should establish the patient's main treatment objective.

Pigmentation, superficial texture, atrophic acne scars and fine lines do not necessarily require the same wavelength or treatment approach.

Skin phototype, pigmentation history, medical history, previous laser treatments, skin sensitivity and expected recovery also need to be considered.

The aim is not to select the highest energy the patient can tolerate.

It is to select an appropriate combination of parameters for the intended treatment response.

Before Selecting Parameters

  • Identify the primary skin concern and confirm that laser treatment is appropriate.
  • Assess skin phototype and the risk of post-inflammatory pigmentation.
  • Review recent sun exposure, tanning and previous skin reactions.
  • Check medications, medical history and applicable contraindications.
  • Choose the wavelength according to the treatment objective.
  • Consider pulse energy and pulse duration together.
  • Review fractional spacing, scan repetitions and overall treatment coverage.
  • Assess the planned thermal effect and expected skin response.
  • Confirm appropriate patient eye protection and room safety.
  • Explain recovery, aftercare and realistic expectations before treatment.
  • Document the settings and patient response to support future treatment planning.

About recommended treatment parameters

Why Reference Settings Are Not Universal Prescriptions

The Thulium Laser Pro Dual™ operation manual includes reference parameter tables for various clinical applications.

These include energy, pulse width, spot spacing, scan repetitions, suggested treatment courses and intervals.

The manufacturer states that these are reference parameters, not fixed settings for every patient.

For practitioners, their value is in understanding the relationship between the settings and the treatment objective.

The final protocol should always reflect the individual patient, the wavelength used, the treatment area and the intended clinical effect.

Pure Tone provides practical, equipment-specific nurse-led training and ongoing clinical support to help practitioners understand how these principles apply to the machine they have purchased.

Planning a treatment course

How Far Apart Should Thulium Laser Treatments Be?

Thulium treatments are commonly delivered as a course, but there is no single interval that is optimal for every patient or indication.

At Pure Tone, our usual starting point is to schedule treatments approximately four weeks apart.

This is consistent with many published fractional laser treatment protocols, but it should not be interpreted as a scientifically established optimum for every application.

More intensive treatments, patients at greater risk of pigmentary changes or those requiring additional recovery may benefit from longer intervals.

Intervals of six to eight weeks may therefore be appropriate in selected circumstances.

A further session should only proceed when the skin has recovered sufficiently and the practitioner considers it appropriate.

Recovery and skin response

Treatment Settings Also Influence Aftercare

Post-treatment care should be planned around the actual response of the skin, not simply the name of the laser treatment.

Gentler fractional treatments may produce limited redness and warmth, while stronger treatments can result in more noticeable dryness, flaking, bronzing or surface disruption.

Donna Cummings, Aesthetic Nurse and Pure Tone trainer, typically uses a chilled, single-use facial mask soaked in sterile saline to help cool and calm the skin immediately following treatment, where appropriate.

The skin can be gently cleaned with cool or tepid water as directed by the practitioner.

Patients are generally advised to avoid hot showers, hot baths, saunas, swimming, ordinary facial cleansers and other potentially irritating products during the initial 24–36 hours.

More intensive treatments may require different or longer precautions.

Supporting Skin Recovery

Pure Tone's R7 Regenerating and Moisturising Cream is designed for post-laser skin care and is commonly used following treatment.

Donna's usual recommendation is twice-daily application for seven days, with additional applications where the skin requires them.

Avoidance of direct sunlight is particularly important during recovery.

Where outdoor exposure cannot be avoided, S7 Recovery and Regeneration Sun Cream SPF50+ may provide additional protection, provided the practitioner considers the treated skin suitable for sunscreen application.

Sunscreen should be reapplied according to the product instructions and exposure.

S7 is an additional protective measure, not a substitute for staying out of the sun.

Explore R7 Cream →

Explore S7 SPF50+ →

These are general aftercare principles. The treating practitioner should determine the appropriate routine according to the wavelength, settings, skin response and individual patient circumstances.

Pure Tone Thulium Laser Pro Dual professional 1927nm Thulium and 1550nm Erbium Glass fractional laser platform
Thulium Laser Pro Dual™ combines 1927nm Thulium and 1550nm Erbium Glass within one professional fractional laser platform.

Professional clinic technology

Thulium Laser Pro Dual™

Two fractional wavelengths with adjustable treatment controls for professional skin-rejuvenation applications.

Thulium Laser Pro Dual™ brings together the relatively superficial treatment applications of 1927nm Thulium and the deeper dermal remodelling potential of 1550nm Erbium Glass.

The system provides control over pulse energy, pulse duration, fractional spacing, scan coverage and repeated delivery, allowing a trained practitioner to develop an appropriate treatment plan.

For clinics considering dual-wavelength technology, understanding those controls is essential when evaluating how the machine would fit within an existing treatment menu.

Thulium Laser Pro Dual™: Key Technical Features

  • Wavelengths: 1927nm Thulium and 1550nm Erbium Glass
  • Laser technology: Dual-wavelength fractional fibre laser platform
  • Pulse energy: Adjustable, measured in millijoules
  • Pulse width: Adjustable, measured in milliseconds
  • Fractional spacing: Adjustable treatment-point distribution
  • Scan settings: Selectable shapes and treatment area dimensions
  • Repeated scans: Adjustable according to the machine's controls
  • Treatment delivery: Professional handpiece and scanning system

A note on dual-wavelength treatment

Can the Two Wavelengths Be Used Together?

Published clinical research involving comparable dual-wavelength systems has investigated the use of 1927nm and 1550nm during the same appointment.

However, same-session treatment should not be interpreted as performing two full-intensity treatments consecutively.

The cumulative thermal effect depends on the parameters selected for each wavelength, the treatment area and the response of the skin.

This is especially important when the initial 1927nm treatment has produced marked epidermal disruption or visible ablation.

For some patients, separate appointments may be more appropriate.

Pure Tone is continuing to evaluate combination and stacked laser treatments with an experienced laser specialist, including protocols involving Thulium, Erbium Glass and fractional CO₂ technology.

Further practical guidance will be shared following clinical review of those treatment approaches.

Technology · Training · Support

Understanding the Machine Is Part of Professional Training

Learning what the controls mean is the starting point. Understanding when and how to use them requires hands-on training and clinical judgement.

CPD-Certified Nurse-Led Training

Practical, equipment-specific training delivered by qualified aesthetics nurses.

Training at Your Clinic

Our trainers travel to the purchasing clinic and provide one-to-one practical training on the installed equipment.

Ongoing Clinical Support

Continued clinical and technical support is available as practitioners develop their experience with the machine.

Common technical questions

Thulium Laser Settings FAQs

What does mJ mean on a Thulium laser?

mJ stands for millijoules, a measurement of energy. On Thulium Laser Pro Dual™, the treatment tables express energy values in mJ for both 1927nm and 1550nm.

What is pulse width?

Pulse width is the duration of a laser pulse, usually measured in milliseconds. It is one factor influencing the delivery of heat to tissue.

Is pulse energy the same as laser power?

No. Pulse energy describes a quantity of energy, whereas power describes the rate of energy delivery. Pulse duration also affects the relationship between these measurements.

What does spot spacing control?

Spot spacing affects the distance between individual fractional treatment points within the scan pattern. It therefore influences treatment coverage.

What does overlap mean on Thulium Laser Pro Dual?

The machine's manual describes Overlap as the number of scan repetitions. It should not be confused with a percentage measurement of physical spot overlap.

Can the same settings be used for 1927nm and 1550nm?

No. The two wavelengths have different tissue absorption characteristics and typical treatment applications. Settings should be selected specifically for the wavelength, patient and intended treatment response.

Does higher energy always produce better results?

No. Higher energy may increase treatment intensity, but the appropriate settings depend on the patient's skin, treatment objective, fractional coverage and other parameters.

Can a 1927nm Thulium treatment cause visible ablation?

Yes. Although 1927nm Thulium is commonly described as non-ablative, the Pure Tone system can produce visible surface ablation at very high settings. Treatment intensity and recovery therefore vary.

How often should Thulium treatments be performed?

At Pure Tone, approximately four weeks is a common starting interval. Longer intervals may be appropriate depending on treatment intensity, skin response and clinical assessment.

Are recommended settings suitable for every patient?

No. Reference parameters are intended to guide trained practitioners, not replace individual clinical assessment. Skin type, medical history, treatment area and response must be considered.

Does Pure Tone provide training on treatment settings?

Yes. Pure Tone provides CPD-certified, nurse-led training for professional equipment, including practical machine operation and treatment considerations, with ongoing clinical support.

Final thoughts

Understand the Settings. Understand the Skin.

Energy, pulse width, spot spacing and repeated scans are not independent decisions.

Together with the wavelength, they influence where energy is delivered and how the skin responds.

For practitioners, the objective is not to memorise one set of numbers, but to understand the technology well enough to select and follow an appropriate clinical protocol.

The patient, the treatment objective and the observed skin response must always guide the treatment plan.